Item | Content |
---|---|
Product Name | LQ-DCP |
Chemical Name | Dicumyl Peroxide |
Molecular Formula | C₁₈H₂₂O₂ |
Molecular Weight | 270.4 |
Theoretical Active Oxygen Content | 5.92% |
CAS No. | 80-43-3 |
Einecs | 201-279-3 |
Major Decomposition Products
Decomposition Product |
---|
Phenylacetone |
Methane |
2-Phenylisopropanol |
Safety Indicators
Half-Life (Chlorobenzene Solution) | Temperature |
---|---|
0.1 hour | 153°C |
1 hour | 132°C |
10 hours | 112°C |
Thermal Stability Data
Thermal Stability Parameter | Temperature |
---|---|
Self-accelerating Decomposition Temperature (SADT) | 75°C |
Critical Temperature (Tem) | 70°C |
Storage Temperature (Tsmax) | --/15°C |
Technical Standards
Item | Content |
---|---|
Appearance | White crystalline solid |
Purity | 99% min |
Melting Point | 39-40°C |
Packaging
Item | Content |
---|---|
Standard Packaging | 20 kg corrugated cardboard box (4 x 5 kg plastic bags) |
Storage Classification | Class F Organic Peroxide Solid, UN No. 3110, Class 5.2 |
Safety Considerations
Precaution | Description |
---|---|
Avoid Fire and Heat | Keep away from fire, open flames, and heat sources. |
Avoid Contact with Reducers | Avoid contact with reducing agents (e.g., amines), acids, bases, and heavy metal compounds (e.g., accelerators, metal soaps). |
Refer to MSDS | Always consult the product's safety data sheet (MSDS) for detailed information. |
Usage
Application | Details |
---|---|
Styrene Polymerization | Common initiator for styrene polymerization. Also used as a flame retardant aid in polystyrene production. |
Rubber Crosslinking Agent | One of the most important crosslinking agents for rubber. |
Storage Conditions
Storage Precaution | Details |
---|---|
Storage Environment | Keep packaging tightly sealed and in a well-ventilated area. Maximum storage temperature of 30°C. |
Avoid Contact with | Reducing agents (amines), acids, bases, heavy metal compounds (accelerators, metal soaps). |
Separation from Handling | No repackaging or handling inside the storage area. |
Storage Stability
Storage Condition | Details |
---|---|
Stability | Product quality is guaranteed within 3 months under proper storage conditions. |
Fire Protection
Fire Protection | Details |
---|---|
Small Fire Handling | Use dry powder or CO₂ fire extinguishers. Use large amounts of water to prevent re-ignition. |
Large Fire Handling | Use large quantities of water spray from a safe distance to extinguish the fire. |