LQ-EEP-AT50 Bis-(2-Ethoxy)ethyl peroxydicarbonate 763-69-9

ItemContent
Product NameInitiator LQ-EEP-AT50
English NameBis-(2-Ethoxy)ethyl peroxydicarbonate
Molecular FormulaC₁₀H₁₈O₈
Molecular Weight266.2
Theoretical Active Oxygen Content6.02%
Actual Active Oxygen Content3.01%
CAS No.763-69-9
UN No.3115
GradeClass II dangerous goods packaging, no rail or air transport allowed

Main Decomposition Products

Decomposition ProductsSubstances
Major Decomposition ProductsCO₂, 2-ethoxyhexanol, etc.

Safety Indicators

Half-Life (measured in chlorobenzene solution)Temperature
0.1 hour76℃
1 hour57℃
10 hours40℃
Thermal Stability DataTemperature
Self-accelerating Decomposition Temperature (SADT)15℃
Critical Temperature (Tem)5℃
Control Temperature (Tc)-5℃
Storage Temperature (Tsmax/TSmin)-15℃ / --

Technical Specifications

ItemContent
AppearanceColorless or pale yellow transparent liquid, free of visible impurities
Content50.01%
Inorganic and Organic Hydrolyzable Chlorides150 mg/kg max.

Applications

ApplicationDescription
Polymerization of Vinyl ChlorideUsed as an initiator for polymerization of vinyl chloride, vinylidene chloride, acrylates, and other monomers.

Packaging and Transportation

ItemContent
Standard Packaging20 kg polyethylene packaging
Custom PackagingCan be customized according to customer requirements. Please specify during order

Storage Precautions

PrecautionDescription
Storage LocationKeep packaging sealed and in a well-ventilated area. Max storage temperature: -15℃
Avoid MaterialsKeep away from fire, heat sources, acids, flammable materials, combustible materials, and reducing agents
Storage FacilitiesExplosion-proof lighting and ventilation, switches located outdoors
Handling PrecautionsHandle with care, avoid packaging and container damage, prevent impact and vibration, personal protective equipment required during operations
Safety InstructionsPlease refer to the "Safety Data Sheet (MSDS)"

Product Shelf Life

ItemContent
Shelf LifeQuality guaranteed for three months under proper storage and transportation conditions

Fire Protection

PrecautionDescription
Small Fire HandlingUse foam or dry powder fire extinguishers for small fires
Large Fire HandlingEvacuate to a safe distance and use water hoses to fight the fire, notify fire department for assistance

Send Us Message