Item | Content |
---|---|
Product Name | Initiator LQ-IPP-C50 |
English Name | Diisopropyl peroxydicarbonate |
Molecular Formula | C₈H₁₄O₆ |
Molecular Weight | 206 |
Theoretical Active Oxygen Content | 7.77% |
Actual Active Oxygen Content | 3.88% |
CAS No. | 105-64-6 |
UN No. | 3119 |
Classification | Organic Peroxide Type C (Liquid), Class 5.2 |
Transport Restrictions | Controlled temperature transport, classified as hazardous |
Physical & Chemical Properties
Property | Description |
---|---|
Appearance | Oil-soluble liquid |
Purity | 50.01% |
Hydrolysable Chlorine (Inorganic & Organic) | ≤150 mg/kg |
Main Decomposition Products
Decomposition Products | Substances |
---|---|
Major Decomposition Products | CO₂, Isopropanol |
Safety Indicators
Half-Life | Temperature |
---|---|
0.1 hour | 82℃ |
1 hour | 64℃ |
10 hours | 48℃ |
Thermal Stability Data | Temperature |
---|---|
Self-accelerating Decomposition Temperature (SADT) | 47℃ |
Critical Temperature (Tem) | 0℃ |
Control Temperature (Tc) | -- |
Storage Temperature (Tsmax/TSmin) | -10℃ / --℃ |
Activation Energy (E) | 72.83 KJ/mol |
Applications
Application | Description |
---|---|
Vinyl Chloride Polymerization | Suitable for aqueous suspension and bulk polymerization of vinyl chloride at 45-65℃. It is a highly active initiator for vinyl chloride polymerization. |
Packaging and Transportation
Item | Content |
---|---|
Standard Packaging | 20 kg polyethylene packaging |
Custom Packaging | Available upon request |
Storage Precautions
Precaution | Description |
---|---|
Storage Conditions | Store in a cool, well-ventilated area, with warehouse temperature not exceeding -10℃ |
Avoid Materials | Keep away from fire sources, heat, acids, flammables, combustibles, and reducing agents |
Handling Precautions | Use explosion-proof lighting and ventilation. Outdoor switches are required. Avoid impacts, vibrations, and rough handling during transportation and repackaging |
Product Shelf Life
Item | Content |
---|---|
Shelf Life | Quality guaranteed for three months under proper storage conditions |
Fire Protection
Precaution | Description |
---|---|
Small Fire Handling | Use foam or dry powder extinguishers for small fires |
Large Fire Handling | Evacuate to a safe distance and use water jets to control flames. Notify the fire department |